Inverter Low-temperature R290/R404A Condensing Unit Supplier

Home / Product / Condensing Unit / Inverter Low-temperature R290/R404A Condensing Unit
Inverter Low-temperature R290/R404A Condensing Unit
  • Inverter Low-temperature R290/R404A Condensing Unit
  • Inverter Low-temperature R290/R404A Condensing Unit
  • Inverter Low-temperature R290/R404A Condensing Unit

Inverter Low-temperature R290/R404A Condensing Unit

Feature

Advantages of Highly unit:
1.  0~30 degrees Celsius common storage temperature, no need to distinguish between medium and high temperature and low temperature
2.  low compressor noise,The test result is only 60 decibels noise at a distance of one meter
3.R290 refrigerant low temperature inverter unit

  • Technical specification
  • About us
  • Get an inquiry

Inverter Low-temperature Condensing Unit(R404A)

 Model UCILX-2H UCILX-3H UCILX-4H UCILX-5H UCILX-6H UCILX-9H
Compressor Model DTH254LDP DTH307LDP DTH356LDP DTH420LDP DTH550LDP DTE752LKTQ
Compressor Operating Frequency  30-85Hz
RangeApplicable Evaporation Temperature +0~-40℃
Unit Horsepower (PH) 2 3 4 5 6 9
Refrigerant R404
Power Supply 1N-220V 50Hz  3N-380V 50Hz 
Fan(DC) Fan Form DC DC DC DC AC AC
Fan Blade Diameter Ф480*1 Ф480*1 Ф480*2 Ф480*2 Ф500*2 Ф500*2
Number 1 1 1 2 2 2
Air volume 1*6000 1*6000 1*6000 2*6000 2*7200 2*7200
Air outlet method Lateral outflow
Capacity
(85Hz)
Evaporating Tempe -5℃ Cooling capacity(W) 5534 6569 7535 8827 13885 17537
Input(kW) 2.21 2.65 3.05 3.65 5.75 7.02
running current(A) 9.64 11.56 13.31 15.93 11.42 13.9
Evaporating Tempe -15℃ Cooling capacity(W) 3728 4375 4989 5942 9326 15123
Input(kW) 1.98 2 2.73 3.25 4.66 6.77
running current(A) 8.64 8.73 11.92 14.18 9.26 13.45
Evaporating Tempe -25℃ Cooling capacity(W) 2435 2857 3217 3796 6795 7826
Input(kW) 1.72 2.06 2.4 2.85 3.32 6.02
running current(A) 7.51 8.99 10.47 12.44 6.59 11.96
Evaporating Tempe -35℃ Cooling capacity(W) 1528 1831 2048 2336 4463 6132
Input(kW) 1.47 1.77 2.03 2.45 4.12 5.61
running current(A) 6.41 7.23 8.86 10.69 8.19 11.14
Interface pipe diameter Outlet pipe 3/8 3/8 1/2 1/2 1/2 5/8“
Suction pipe 5/8 5/8 3/4 3/4 3/4 7/8“
Refrigeration Oil 68HES-H
overall dimension: L*W*H(mm*mm*mm) Package size 1330*577*812 1330*577*812 1330*577*812 1330*577*1342 1330*577*1342 1330*577*1342
Unit size 1277*510*667 1277*510*667 1277*510*667 1277*510*1196 1277*510*1196 1277*510*1196

Inverter Low-temperature Condensing Unit R290

Unit Model UCILZ-02S UCIZ-03S UCIZ-04S UCIZ-05S UCIZ-07S UCIZ-09S
Compressor Model  SONYO C-7RVN113L0B  C-7RVN153L0B C-8RZ420L4BAL C-8RZ486L4AAL C-9RZ580L4AAL C-9RZ700L4AAL
Compressor Operating Frequency Range 30-85Hz
Applicable Evaporation Temperature +0~-40℃
Unit Horsepower (PH) 2 3 4 5 7 9
Refrigerant R290
Power Supply 1N-220V 50Hz  3N-380V 50Hz 
Fan Fan Form DC DC DC DC AC AC
Fan Blade Diameter Ф480*1 Ф480*1 Ф480*1 Ф480*2 Ф500*2 Ф500*2
Number 1 1 1 2 2 2
Air volume 1*6000 1*6000 1*6000 2*6000 2*7200 2*7200
Air outlet method Lateral outflow
compressor capacity
(30Hz)
Evaporating Tempe -5℃ Cooling capacity(W) 1446.4 1747.2 2028.8 2393.6 3014.4 4441.6
 Input(kW) 0.746 0.896 1.037 1.234 1.53 2.163
running current(A) 3.48 4.18 4.84 5.75 3.03 4.29
Evaporating Tempe -15℃ Cooling capacity(W) 960.8 1160.8 1348 1590.4 2151.2 3068
Input(kW) 0.665 0.798 0.924 1.099 1.454 2.011
running current(A) 3.1 3.72 4.31 5.12 2.88 3.99
Evaporating Tempe -25℃ Cooling capacity(W) 614.4 741.6 861.6 1016 1468 2053.6
Input(kW) 0.581 0.698 0.807 0.961 1.359 1.849
running current(A) 2.71 3.25 3.76 4.48 2.69 3.67
Evaporating Tempe -35℃ Cooling capacity(W) 372 449.6 522.4 616 976.8 1470.4
Input(kW) 0.396 0.496 0.539 0.681 1.118 1.673
running current(A) 1.84 2.31 2.51 3.17 2.22 3.32
compressor capacity
(50Hz)
Evaporating Tempe -5℃ Cooling capacity(W) 2503.2 3024 3511.2 4143.2 5517.6 7875.2
Input(kW) 1.319 1.583 1.832 2.18 2.862 3.951
running current(A) 6.15 7.36 8.49 10.17 5.68 7.84
Evaporating Tempe -15℃ Cooling capacity(W) 1664 2009.6 2333.6 2753.6 3947.2 5460.8
Input(kW) 1.176 1.411 1.633 1.943 2.726 3.673
running current(A) 5.48 6.58 7.62 9.06 5.41 7.29
Evaporating Tempe -25℃ Cooling capacity(W) 1063.2 1284 1491.2 1759.2 2495.2 3656
Input(kW) 1.028 1.234 1.428 1.699 2.38 3.377
running current(A) 4.79 5.75 6.66 7.92 4.72 6.7
Evaporating Tempe -35℃ Cooling capacity(W) 644.8 778.4 904 1066.4 1769.6 2524.8
Input(kW) 0.777 0.861 0.987 1.103 1.757 2.446
running current(A) 3.62 4.01 4.6 5.14 3.48 4.85
compressor capacity
(70Hz)
Evaporating Tempe -5℃ Cooling capacity(W) 4126.4 4984.8 5788 6829.6 9702.4 12827.2
Input(kW) 2.19 2.628 3.042 3.62 5.149 6.8
running current(A) 10.22 12.26 14.19 16.89 10.22 13.5
Evaporating Tempe -15℃ Cooling capacity(W) 2743.2 3313.6 3847.2 4539.2 6526.4 8840
Input(kW) 1.952 2.343 2.712 3.227 4.49 6.307
running current(A) 9.1 10.93 12.65 15.09 8.91 12.52
Evaporating Tempe -25℃ Cooling capacity(W) 1752 2116 2456.8 2899.2 4780 6079.2
Input(kW) 1.707 2.049 2.371 2.822 4.15 5.682
running current(A) 7.96 9.56 11.06 13.16 8.24 11.28
Evaporating Tempe -35℃ Cooling capacity(W) 1062.4 1283.2 1490.4 1758.4 3431.2 4661.6
Input(kW) 1.256 1.547 1.722 2.014 3.927 5.26
running current(A) 5.86 7.21 8.03 9.39 7.79 10.44
compressor capacity
(85Hz)
Evaporating Tempe -5℃ Cooling capacity(W) 4427.2 5255.2 6028 7061.6 11108 14029.6
Input(kW) 2.21 2.65 3.05 3.65 5.75 7.02
running current(A) 9.64 11.56 13.31 15.93 11.42 13.9
Evaporating Tempe -15℃ Cooling capacity(W) 2982.4 3500 3991.2 4753.6 7460.8 12098.4
Input(kW) 1.98 2 2.73 3.25 4.66 6.77
running current(A) 8.64 8.73 11.92 14.18 9.26 13.45
Evaporating Tempe -25℃ Cooling capacity(W) 1948 2285.6 2573.6 3036.8 5436 6260.8
Input(kW) 1.72 2.06 2.4 2.85 4.32 6.02
running current(A) 7.51 8.99 10.47 12.44 6.59 11.96
Evaporating Tempe -35℃ Cooling capacity(W) 1222.4 1464.8 1638.4 1868.8 3570.4 4905.6
Input(kW) 1.47 1.77 2.03 2.45 4.12 5.61
running current(A) 6.41 7.23 8.86 10.69 8.19 11.14
Interface pipe diameter Outlet pipe interface 3/8 3/8 1/2 1/2 1/2 5/8“
Suction pipe interface 5/8 5/8 3/4 3/4 3/4 7/8“
overall dimension: L*W*H(mm*mm*mm) Package size 1330*577*812 1330*577*812 1330*577*812 1330*577*1342 1330*577*1342 1330*577*1342
Unit size 1277*510*667 1277*510*667 1277*510*667 1277*510*1196 1277*510*1196 1277*510*1196

Test conditions; Condensation temperature=50 ℃;
This unit has added a control scheme for indoor units, so there is no need to install another control box. It adopts a 4.3 inch industrial touch screen, high and low pressure sensors, and pressure gauges are connected with hoses. The liquid reservoir is equipped with a ball valve or angle valve, and electronic expansion valves are used for throttling;